Vehicle 12-80VDC Direct Connection

Note:
GND
3
4
Note:
Wiring color codes for LXE supplied DC input power cabling:
VX6 Reference Guide
Instructions for using this configuration are contained in "VX6 User's Guide" section
titled "Installation".
1
+
3
-
4
6
5

Figure 2-40 Direct Vehicle Power Connection Cable (12 Ft.)

1
2
5

Figure 2-41 Connecting the Power Cable to the Vehicle

Correct electrical polarity is required for safe and proper installation. Connecting the
cable to the VX6 with the polarity reversed will cause the VX6's fuse to be blown. See the
following table for wire color-coding specifics.
Vehicle Supply
+12 - 80VDC
Return
Vehicle Chassis

Figure 2-42 Vehicle Connection Wiring Color Codes

2
6
7
8
Wire Color
(DC +)
Red with White Stripe
(DC -)
Red with Black Stripe
(GND)
Power Supply
1. To Vehicle Battery
2. To Vehicle
Mounted Device
or UPS Battery
Pack
3. White (DC+)
4. Black (DC-)
5. Green (GND)
6. 12 – 80 VDC
1. Vehicle Electrical
System
2. 5 Amp Slow
Blow Fuse
3. DC +
4. DC -
5. Vehicle Chassis
6. Red / White
7. Red /Black
8. Green
Green