Application Configuration
specified, the user will be prompted for the password before entering administration mode. The
password prompt remains on the display until a valid password is entered.
Option
Filename
Title
Arguments
Order
Internet
Launch Button
Global Key
Global Delay
Input Panel
Clear Button
E-EQ-VX6RG-F
Explanation
Default is blank. Move the cursor to the Filename text box and either type
the application path or tap the Browse button (the ... button). The standard
Windows CE Browse dialog is displayed. After selecting the application
from the Browse dialog, tap OK.
Default is blank. Enter the Title to be associated with the application. The
assumption is that multiple copies of the same application may need unique
titles in order to differentiate them in the application switcher panel.
Default is blank. Enter the command line parameters for the application in
the Arguments text box.
Default is 1. Enter the Order in which the application is to be loaded or
presented to the end-user. Applications are launched in lowest to highest
number order.
Default is Disabled. Enable the Internet checkbox to use the End-user
Internet Explorer (EUIE.EXE) When the checkbox is enabled, the Internet
Menu and Internet Status are available. See the section titled End-user
Internet Explorer (EUIE) for more details.
See following section titled Launch Button.
Note:
AppLock Administrator Control panel file Launch option does not
inter-relate with similarly-named options contained in other LXE
Control Panels.
Default is Ctrl+Spc. Select the Global Key key sequence the end-user is to
press when switching between applications. The Global Key default key
sequence must be defined by the AppLock Administrator. The Global key
is presented to the end-user as the Activation key.
Default is 10 seconds. Enter the number of seconds that Applications must
wait before starting to run after reboot.
Note:
Delay (Global) may not be available in all versions of AppLock.
You can simulate a Global Delay function by setting a delay for
the first application (lowest Order) launched and setting the delay
to 0 for all other applications. See Boot Options.
Default is Disabled. Enable (check) to show the Keyboard option on the
Switchpad menu. When enabled the input panel cannot be enabled or
disabled for each individual application, and is available to the user for all
configured applications.
Tap the Clear button to clear all currently displayed Filename or
Application information. The Global settings are not cleared.