Advertisement

AppLock Error Messages
Message
Switching to admin-hotkey press
Switching to admin-kbdhook.dll not
found
Switching to admin-keyboard hook
initialization failure
Switching to admin-registry read
failure
Switching to TaskbarScreenMode
Switching to user mode
Switching to user-hotkey press
Taskbar hook failure
Taskbar hook OK
Timeout looking for app window
ToUser after admin, not at boot
ToUser after admin-app still open
ToUser after admin-no app or cmd
line change
E-EQ-VX6RG-F
Explanation and/or corrective action
The system is currently in user mode and is now
switching to admin mode. The switch occurred because
of a hotkey press by the administrator.
The keyboard hook load failed, so AppLock switches to
admin mode. If a password is specified, the password
prompt is displayed and remains until a valid password
is entered.
If the keyboard hook initialization fails, AppLock
switches to admin mode. If a password is specified, the
password prompt is displayed and remains until a valid
password is entered.
See the explanation of the "Registry read failure" above.
AppLock is switching into Admin mode. If a password
has been configured, the prompt will be displayed and
will not be dismissed until a valid password is entered.
In administration mode, the taskbar is visible and
enabled.
The registry was successfully read and AppLock is
starting the process to switch to user mode.
The system is currently in admin mode and is now
switching to user mode. The switch occurred because of
a hotkey press by the administrator.
AppLock is unable to control the taskbar to prevent the
locked application from re-enabling it.
AppLock successfully installed control of the taskbar.
After the application is launched, AppLock must wait
until the application has initialized itself before
proceeding. The application did not start successfully
and AppLock has timed out.
The user mode switch is attempted when the device
boots and after the administrator presses the hotkey. The
mode switch is being attempted after a hotkey press.
The switch to user mode is being made via a hotkey
press and the administrator has left the application open
and has not made any changes in the configuration.
If user mode is being entered via a hotkey press, the
administrator may have left the configured application
open. If so, AppLock does not launch the application
again unless a new application or command line has
been specified; otherwise, it just locks it.
317
Level
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_PROCESSING
LOG_EX
LOG_PROCESSING
LOG_PROCESSING
LOG_ERROR
LOG_EX
LOG_ERROR
LOG_EX
LOG_EX
LOG_EX
VX6 Reference Guide

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents