Mitsubishi Electric Freqrol-A100 Instruction Manual page 53

Freqrol-a100 series transistorized inverter for variable torque loads
Table of Contents

Advertisement

(2) Entering the running frequency from the outside and making start and stop from the PU (Pr.79=4)
For details of changing the parameter setting, see page 62.
0-
Operation procedure-
-
.
-
Switch the power on.
Note.
1
:The startlng termmals
(STF, STR) of the inverter
are ~nvahd.
The Inverter cannot be
started ~f the [FWD] or
[REV] key
IS
pressed and
the level of the frequency
settlng s ~ g n a l
IS
then
r a ~ s e d
~ e t ' " 4 " in Pr. 79 "operation mode
The combined operation mode is
selected and the operation mode
indication on the display changes to
"PU+E".
,
.......
Enter the running frequency signal
(select the multi-speed signal or
turn the frequency setting
potentiometer).
.
.
.......
Press the [FWD] or [REV] key. (Note 1)
The motor starts running.
The state of the output frequency is
shown on the display.
.......
Press the [STOP] key of the PU.
The motor is decelerated to a stop.