Pr. 60
o
Pr.
60
"intelligent mode selection"
By selecting this parameter, the inverter is automatically ad-
justed as if the appropriate value had been set in each parame-
ter, without needing to set the acceleration and deceleration
times and V/F pattern. This operation mode is useful to perform
operation immediately without making fine parameter settings.
(Note
I I
he
inverter automatically selects appropriate parameters
-
Pr.
60
Set
Value
0
(factory
setting)
Function
Set
I
Operation
The self-learning system
automatically sets the boos
value, acceleration and de
celeration times so that the
current during acceleration,
3ptimum deceleration is lower thar
xcelera- the rated current of the in
tionlde-
verter. Optimum operatior
:eleration can be carried out by full)
node
utilizing the inverter capabili
ties in the rated continuour
range.
Appropriate for application:
where the load will not var)
largelv. (Note
6)
Tunes the inverter outpu
voltage online so that the in
verter output voltage is mini
Energy-
mized during constant-speec
Saving
operation. (Note 2 )
mode
Appropriate for energy-sav
ing applications such as far
land pump.
9utomat-
cally Set
Parame-
ters
-
Pr. 0
Pr.
7
Pr.
8
Output
voltage
Note: 1. When more accurate control is required for application, set
parameters manually.
2. Because of the learning system, this control is not valid the
first time.
3. If an overvoltage (OV3) trip has occurred during operation in
the optimum acceleration/deceleration mode, reset Pr. 8 "de-
celeration timen t o a slightly larger value and restart opera-
tion in this mode.
4. When either of "3 or 4" has been set in Pr. 60, the parameters
dedicated to intelligent mode Pr. 61 to 63 are valid.
Pr. 61 to
64,
which need not be set unless required, may be
set to improve performance. Set "0" in Pr. 60 to automatically
set "9999" (factory setting) in Pr. 61 to 63.
5.
When the motor is decelerated to a stop in the energy-saving
mode, the deceleration time may become longer than the
setting.
Also, since an overvoltage is more likely t o occur in this mode
than in the constant-torque load characteristic, set a longer
deceleration time.
6. The optimum acceleration/deceleration mode is only valid for
the frequency setting of 30.01Hz or higher.