(From the preceding page)
(2) Setting of the
frequency
setting voltage
gain
12) Apply the voltage of 5 V.
I
......
Since 50Hz is set against 5V in
this example, 5V is applied.
.=
The precedng
set value
IS
d~splayed
+ -
The
current set voltage across
terminals 2
and
5
IS
d~splayed In
9)
Press the [SHIFT] key,
...
The current set value of Pr. 903
then the [READ] key.
IS
d~splayed.
11) Press the [WRITE] key.
..
The cursor (+) moves to the set
voltage.
The d~splayed
value
IS
changed accordmg as
the
set voltage
10) Usmg the numeral
...........
The data on the right
IS
d ~ s -
The value selected
In
Pr 73 (5V In
thls
809
WV aln
example)
IS
100%
keys, enter 50.
played.
,
, ,
-Set
the voltage across terminals
Note: 1. The current input (Pr. 904, Pr. 905) can also be set in a similar manner.
2. Pr. 903 remains unchanged if the value set in Pr. 20 "acc./dec. reference frequency" is
changed.
I
2 and 5 until 100% is achieved.
13) Press the [WRITE] key.
..
The set value is stored into mem-
ory and gain setting is complete.
I
below:
The adjustment of the frequency set-
I
ting voltage bias and gain is complete.
v
0
5v
,
EXTV
corn leted
--
100.OO/~ may not be displayed.
The setting is complete as shown

Hide quick links: