3

Escape the elevating section.

(1)
Check that the power switch for control box A is OFF.
(Power LED is off.)
(2)
Connect the Ni-E connector on control box A with
the BOX connector on the rear of the microscope
using a cable.
(3)
Plug in the power cord to the AC inlet of the control
box A and the other end of the power cord to a wall
outlet.
(4)
Turn on the power for control box A. (Power LED
turns on.)
(5)
Turn the focus knob to move the elevating section to
the upper limit.
(6)
Turn off the power for control box A. (Power LED
turns off.)
(7)
Remove the power cord from the wall outlet.
(8)
Remove the connected connection cable and power
cord from the microscope and control box A.
4

Attach the motorized ND filter wheel (optional).

Tool: Hex driver (2 mm across flats)
(1)
Attach it to lamphouse mount at the rear of the
microscope base and tighten the fixing screws from
the top.
(2)
Connect the motorized ND filter wheel cable to the
ND connector on the connector box.
5

Attach the DIA motorized shutter (optional).

The motorized shutter is attached by Nikon.
Contact your nearest Nikon representative when the DIA
motorized shutter needs to be mounted or removed.
Chapter 1
Assembly
Power LED
Power switch
Attaching the motorized ND filter wheel
8
Ni-E (Connect to Ni-E BOX)
OFF ON
FASTENING
N i - E
POSITION SW
This device complies with Part
15 of the FCC Rules. Operation
is subject to the following
two conditions:
(1) this device may not cause
harmful interference, and
(2) this device must accept any
interference received,
including interference that
may cause undesired
operation.
This Class A digital apparatus
complies with Canadian ICES-003.
Cet appareil numérique de la
classe A est confirme à la
norme NMB-003 du Canada.
MODEL NI-CTLA
5 4 0 0 0 1
MADE IN JAPAN
100-240V~ 5A 50/60Hz
AC inlet
Control Box A (Front/Rear)
CONTACT ARM2
EPI SHUTTER
USB
MODEL ECLIPSE Ni-E
NIKON CORPORATION
9 1 0 0 0 1
TOKYO, JAPAN
M A D E I N J A P A N
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est confirme à la norme NMB-003 du Canada.
DSC1
HGFIE
BOX
BOX (Connect to Ni-E for the control box A)
Ni-E Microscope (Rear)
ND filter wheel
fixing screw
ND
ND
NC B
8
32
11
OU T
IN
CONTACT
ARM1
LAMP

Hide quick links: