NEC NEAX 2000 IPS System Manual page 335

Internet protocol server ccis system manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

D
STEP 3
CM8A
Example: To set the 7:00 AM to 9:00 PM for
STEP 4
STEP 5
END
Operating Procedure
No manual operation is required.
DESCRIPTION
Assign the starting time for the Toll
Restriction and Route Pattern
number to the Time Pattern num-
ber assigned by Step 2. Set the
Starting Time as shown below.
the Toll Restriction, enter the fol-
lowing starting times one by one.
0700 (7:00 AM-7:30 AM)
0730 (7:30 AM-8:00 AM)
0800 (8:00 AM-8:30 AM)
. .
.
2030 (8:30 AM-9:00 AM)
Assign a TR Pattern number to the
Route Pattern number assigned by
Step 3.
Assign a Toll Restriction Pattern
number assigned by CM81 to the
TR Pattern number assigned by
Step 4.
CHAPTER 3 SYSTEM DATA PROGRAMMING
Y=2000-2007 Time Pattern No. 0-7
(1)
XX ZZ (Starting Time)
XX : 00-23 (Hours)
ZZ : 00/30 (Minutes)
(2)
0000-0255: Route Pattern No. 000-255
If Tenant Pattern is required, set 1000-1015
(Tenant Pattern No. 0-15).
Y=0000-0255 Route Pattern No. 000-255
(1)
1
(2)
XXX: 000-255: TR Pattern No.
Y=5000-5255 TR Pattern No. 000-255
(1)
000
(2)
00-15 : Toll Restriction Pattern No. 00-15
– 321 –
TOLL RESTRICTION-3/6 DIGITS-CCIS
DATA
NWA-008853-001 Rev.3.0
97ch3005.fm