NEC NEAX 2000 IPS System Manual page 180

Internet protocol server ccis system manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

CALL FORWARDING-DON'T ANSWER-CCIS/MULTIPLE CALL FORWARDING-DON'T ANSWER-CCIS
A
CM35
To apply this feature to incoming calls, set the
trunk route combinations for Tandem connec-
tion.
CM36
CM08
Allow Call Forwarding-Outside-CCIS.
Specify the Call Forwarding-Don't Answer-
Outside setting operation.
Specify the system operation when terminat-
ing a DID call to station with Call Forwarding-
Don't Answer set to a busy destination station.
(Destination station has no call forwarding
set.)
Assign whether an extension can set the desti-
nation of Call Forwarding-Don't Answer-Out-
side by entering only a trunk access code.
Assign whether the system should check the
trunk restriction class of the forwarded station
during Call Forwarding-Don't Answer-Out-
side.
B
DESCRIPTION
CHAPTER 3 SYSTEM DATA PROGRAMMING
Y=05
(1)
00-63: Trunk Route No.
(2)
1 : Release Signal arrives
Y=0
(1)
XX ZZ
XX: 00-63 (Incoming Trunk Route)
ZZ : 00-63 (Outgoing Trunk Route)
(2)
0: Allow
(1)
370
(2)
1 : Allowed
(1)
222
(2)
0 : The feature is set when the station
goes on hook/when receiving Service
Set Tone (ORT time out)
1 : The feature is set when receiving Ser-
vice Set Tone (ORT time out)
(1)
449
(2)
0 : Ring continuously at forwarded DID
station
1 : Drop to busy signal after time set by
CM41 Y=0>01
(1)
386
(2)
0 : Restricted
1 : Allowed
(1)
387
(2)
0 : Follow the trunk restriction class
1 : No check
– 166 –
DATA
NWA-008853-001 Rev.3.0
97ch3002.fm

Advertisement

Table of Contents
loading