4

Technical Data

4.1

Front Panel

4.2

Power Supply

4.3

Ambient Conditions

Max. ambient temperature
Max. temperature gradient
Relative humidity
Display
Operation
Surface – front panel
Degree of protection
Interface
Fig.4-1:
Technical data: Front VDP 92.3
Power supply: display
The VDP 92.3 has to be supplied with 24 V/ 2 A using the X1S1 connector.
Voltage
Current consumption
Power supply: VAM hardware
Voltage supply
Logic supply U
L
Current consumption
from U
L
Input an output supply
U
Q
Current consumption
from U
Q
Fuse
Reverse voltage pro‐
tection
In operation
+5 °C up to +45 °C
Temperature change up to 3°C per minute
Climatic class 3K3 according to
EN 60721, condensation not permissible.
Electric Drives
| Bosch Rexroth AG
and Controls
15" TFT, 1024 × 768 pixels, 256,000 colors
Key operation
Traffic white
Front panel IP 54
Front type 1 according to NEMA (UL)
USB port, cover: degree of protection IP 54
24 VDC
2 A max.
Electrically isolated
24 V DC (19.2 to 30 V), PELV
0.5 A max.
24 V DC (19.2 to 30 V), PELV
1.7 A max.
SMD fuse 3 A
Integrated
Storage / Transport
-20 °C up to +60 °C
Not defined
Climatic class 3K3 according to
EN 60721, condensation not per‐
missible.
15/52