Panasonic KX-NS1000 Installation Manual page 274

Pure ip-pbx
Hide thumbs Also See for KX-NS1000:
Table of Contents

Advertisement

5.9.4 Installing IP Phones at a Remote Site with a Built-in Media Relay Gateway
Application
RTP (UDP)
*1
The port number for NTP that the KX-NS1000 uses is fixed to 123.
*2
The port number ranges must be within the range of RTP/RTCP for NAT traversal (16000–18047).
Up to 4 IP addresses can be assigned to the KX-NS1000's optional DSP cards. The following example shows the port number ranges
set for each IP address:
[Example]
Port forward destination
DSP#1–1
DSP#1–2
DSP#2–1
DSP#2–2
Installing KX-NT500 series IP-PTs at a remote site with Built-in Media Relay
Gateway
You can install KX-NT500 series IP-PTs at the remote site directly or from the local site as follows.
1.
Register the IP-PT. For details, refer to "5.9.1 Registering IP Telephones".
2.
Programme the settings for the IP-PT.
a.
Click Setup ® PBX Configuration ® Configuration ® Slot.
b.
Click Virtual ® V-IPEXT32.
c.
Move the mouse pointer over the V-IPEXT32 card (Virtual 32-Channel VoIP Extension Card).
A menu will be shown under the mouse pointer.
d.
Click Port Property.
e.
Click the Remote Place tab.
f.
Configure the items shown below.
Change the value to Remote (MRG) for Phone Location.
g.
Click OK.
3.
Unplug the AC adaptor of the IP-PT, and then plug it in again to reboot the IP-PT manually. The IP-PT will
download settings automatically.
Installing KX-UT series SIP phones at a remote site with Built-in Media Relay
Gateway
There are 2 methods to install KX-UT series SIP phones at a remote site:
Set up the phones at the main site using the KX-NS1000, and then send them to the remote site.
Set up the phones without connecting them to the KX-NS1000 at the main site, and then send them to the
remote site.
274
Installation Manual
LAN Side Port Number
Start/End RTP (UDP) Port No.
(Use port numbers that are in the
range of the RTP ports that the
KX-NS1000 uses.)
*2
Make sure the RTP Start Port (UDP) and the RTP End Port (UDP) specified
for the router are in the range of the RTP ports that the KX-NS1000 uses.
For the range of RTP port numbers that the KX-NS1000 uses, refer to "Port
Numbers for Optional DSP Cards" in "8.5 Port Security".
WAN Side Port Number
Start/End RTP (UDP) Port No.
(Use port numbers that are in the
range of the RTP ports that the
KX-NS1000 uses.)
Port number range
16000–16511
16512–17023
17024–17535
17536–18047
*2
*2

Advertisement