Maintenance Function; Maintenance Time Setting; Function Of The Maintenance Timing Setting - Mitsubishi GT16 User Manual

Hide thumbs Also See for GT16:
Table of Contents

Advertisement

2.4 Maintenance Function

2.4.1

Maintenance time setting

Energization time, touch count and writing times used as a standard for the maintenance time are set.
For using the maintenance time notification, a battery is required.
Refer to the following for the details of battery.

Function of the maintenance timing setting

For using the maintenance time notification, a battery is required.
When setting the time or count to notify the maintenance time, refer to the life described in "(Hardware) Section 3.2"
as a guide.
The maintenance time notification is output by the following two methods.
•Outputs to GOT special register (GS680).
•Outputs as system alarm
For details of the GOT special register and system alarm, refer to the following.
POINT
POINT
POINT
Switching OFF the maintenance time notification output
The maintenance time notification setting which has been set once is not switched OFF even if changing its setting.
Switch OFF the maintenance time notification by the following methods.
• Execute addition time reset.
• Switch OFF each bit of "maintenance time notification cancel information (GS638)".
Item
Backlight maintenance
time notification period.
(0 to 100000 hour)
Display section
maintenance time
notification period
(0 to 100000 hour)
Touch key maintenance
time notification count
(0 to 2000000times)
Built-in flash memory
maintenance time
notification count
(0 to 200000times)
2 - 66
2.4 Maintenance Function
(Hardware) 8. OPTION
•GT Designer3 Version1 Screen Design Manual (Fundamentals)
•GT Designer3 Version1 Screen Design Manual (Functions)
•GT Designer2 Version
Description
Sets energization time for the maintenance
notification output.
When 0, no message notification.
The time is counted only when backlight is lit, in
every ten minutes.
Sets energization time for the maintenance
notification output.
When 0, no message notification.
The time is counted only when energized, in
every ten minutes.
Sets touch key touching count for the
maintenance notification output.
When 0, no message notification.
Counts by every screen touch.
Sets built-in flash memory writing count for the
maintenance notification output.
When 0, no message notification.
Counts by every writing in built-in flash memory.
Screen Design Manual
Setting range
Unit
0 to 100
1000
<At factory
hours
shipment: 0>
0 to 100
1000
<At factory
hours
shipment: 0>
0 to 200
10000
<At factory
times
shipment: 0>
0 to 200
1000
<At factory
times
shipment: 0>
Maintenance
points
Reference
(Hardware)
9.5 Backlight
Shutoff
Detection
and
Replacement

Advertisement