(1) Communication parameter setting by GT Designer3 or GT Designer2
Set the communication parameters for each communication driver at [Communication Settings] in [Controller
Setting] of GT Designer3 or in [System Environment] of GT Designer2.
When change the communication parameters after downloading project data, change the setting at
communication detail setting of GOT.
•GOT1000 Series Connection Manual for GT Works3 and a controller used
(1.1 Setting the Communication Interface)
•GT Designer2 Version
(3.7 Communication Interface Setting (Communication setting))
(2) For the Ethernet multiple connection
Touch the driver display BOX of the Ethernet connection, and then the communication detail setting screen of
Channel No. 1 is displayed.
Assign Ethernet I/F
Several drivers are assigned to the same Ethernet interface. However, only one GOT IP address is assigned per
interface.
By changing the settings of one interface, the GOT IP address, GOT port No. download, default gateway and subnet
mask settings of other drivers, which are assigned to the same interface, are also changed.
Screen Design Manual
1.
Touch the [Assign Ethernet I/F] button in
Communication Setting.
2.
Touch the driver display BOX of the
communication parameter to be set in the
[Ethernet I/F assignment] screen.
3.2 Communication Detail Setting
1
2
3
4
5
6
7
3 - 14