Mitsubishi GT16 User Manual page 116

Hide thumbs Also See for GT16:
Table of Contents

Advertisement

POINT
POINT
POINT
Precautions for communications between GOT and controller
(1) Installing communication driver and downloading Communication Setting
The followings below are required for the communication interface to communicate with the controller.
1) Installing communication drivers (Up to 4 communication drivers)
2) Assigning the channel number and communication driver for the communication
interface
3) Downloading the contents (project data) assigned in 2).
Perform1), 2), 3) by GT Designer3 or GT designer2.
Refer to the following for details.
(2) When Communication Setting has not been downloaded.
The GOT automatically assigns the installed communication driver in the order of 1 to 4 as follows.
(Only the extend interface is assigned automatically.)
1)
3)
1) ChNo.1, Communication driver installed at 1st
2) ChNo.2, Communication driver installed at 2nd
3) ChNo.3, Communication driver installed at 3rd
4) ChNo.4, Communication driver installed at 4th
3 - 5
3.1 Communication Setting
• GOT1000 Series Connection Manual for GT Works3 and a controller used
(1.1 Setting the Communication Interface)
• GT Designer2 Version
(3.7 Communication Interface Setting (Communication Settings))
• GT Designer3 Version1 Screen Design Manual (Fundamentals)
(7.3.7 Reading project data)
• GT Designer2 Version
(8.3.1 Downloading project data [PC to GOT])
Screen Design Manual
Basic Operation/Data Transfer Manual
2)
4)

Advertisement

Table of Contents
loading

Table of Contents