Lexmark CX310n Service Manual page 85

Machine type 7527-2xx, -4xx, -63x
Hide thumbs Also See for CX310n:
Table of Contents

Advertisement

Actions
Step 3
Open the front cover, and check the power cable (A) on the left side of
the fuser.
Remove the right cover assembly. See
on page
223.
Check the thermistor cables and connections (B) on the right side of the
fuser.
Are the cables or connectors damaged?
"Right cover assembly removal"
Diagnostic information
85
Yes
No
Repair the cables. If the
Go to step 5.
cables cannot be
repaired, then replace
the fuser. See
"Fuser
assembly removal" on
page
257.