Fuser Drive Motor Assembly Removal - Lexmark CX310n Service Manual

Machine type 7527-2xx, -4xx, -63x
Hide thumbs Also See for CX310n:
Table of Contents

Advertisement

8
Remove the screw and grounding washer (E) on the right side of the frame.
Note: Be careful to not lose the grounding washer.
9
Rotate the top of the fuser toward the front, and then slide to the left to align the fuser side frames with the flat
area of the shaft.
10
Lift the fuser, and remove.
Warning—Potential Damage: Be careful to not interfere with or damage the fuser exit sensor to the left of the
fuser when rotating.
Installation note: Install the narrow media flag to the fuser before rotating the fuser into the printer.

Fuser drive motor assembly removal

1
Remove the right cover assembly. See
2
Disconnect the cable (A) from the fuser drive motor assembly.
Note: If you remove the toroid (B) from the cable, be sure to return the toroid to the cable when reinstalling.
"Right cover assembly removal" on page