c
Check the position of the card at the left side of the printer. The small vertical post (D) in the endcap has to be
positioned in the hole above it, as show below.
d
Install the new cable, making sure the connector to the board is locked into position.
Note: Reinstall the screw to hold the HVPS to the right side of the printer.
Imaging unit (IU) removal
Note: The imaging unit is a customer replacement unit and is not a FRU.
Note: The imaging unit contains:
•
Photoconductor unit
•
Developer units
To remove only the photoconductor, remove the entire imaging unit, remove the developer units, place the original
developer units in the new photoconductor, and reinstall the imaging unit. When you replace the imaging kit, you are
replacing both the photoconductor and the developer units.
1
Remove the waste toner bottle. See
2
Remove the toner cartridges.
"Waste toner bottle removal" on page
Repair information
266
304.
7527