Charge-Air Coolant – Draining - MTU 12 V 2000 P12 Operating Instructions Manual

Diesel engine
Table of Contents

Advertisement

7.16.2 Charge-air coolant – Draining
Preconditions
☑ Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Sealing rings
WARNING
Coolant is hot and under pressure.
Risk of injury and scalding!
• Let the engine cool down.
• Wear protective clothing, gloves, and goggles / safety mask.
Draining charge-air coolant
1.
Provide an appropriate container to drain
the coolant into.
2.
Turn breather valve of coolant expansion
tank counterclockwise until the first stop
and allow pressure to escape.
3.
Continue to turn breather valve counter‐
clockwise and remove.
4.
Draw off precipitated corrosion inhibitor oil
from the expansion tank through filler neck.
5.
Open the drain valve at the drain point in
the coolant pipe to the charge-air coolant
cooler and drain the coolant, (see unit man‐
ufacturer).
6.
Open drainage screw on the elbow of the
charge-air coolant pump and drain the cool‐
ant.
7.
Draining of residual coolant:
• At the charge-air cooler.
8.
Close all drain valves and install drain plugs
with new sealing rings.
9.
Set breather valve onto filler neck and close
it.
Part No.
(→ Spare Parts Catalog)
MS150025/02E 2012-10 | Task Description | 139
Qty.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

16 v 2000 p12

Table of Contents