MTU 12 V 2000 P12 Operating Instructions Manual page 44

Diesel engine
Table of Contents

Advertisement

Term
Ambient temperature:
Storage temperature:
Relative humidity
Color:
Material:
Dimensions:
Weight:
Note: Values stated above may be restricted when MCS 5 extension modules are used.
EMI/EMC – Electromagnetic interference (general)
The SAM has been tested according to the following standards and meets the relevant limit values:
Standard
EN 55011
EN 55011
IEC-60533:1999
EC-60533:1999
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 50155
EN 61000-4-17
EN 61000-4-29
IEC 60092-504
EN 50155
Requirements for fulfillment of EMI/EMC limit values are as follows:
• If the housing is not grounded via the mounting plate, it must be connected to housing ground e.g. by
means of a cable with a minimum cross-section of 2.5 mm
• Only twisted-conductor cables may be used to connect sensors and actuators. The maximum length
of unshielded cables is 5 m, of shielded cables 50 m (provided wiring harness resistance allows for
this). Shielding shall be connected in the switchgear cabinet.
44 | Technical Data | MS150025/02E 2012-10
Unit
Value
°C
-40 – +70 with circulating ambient air.
°C
-40 - +100
%
5 – 97, no condensation.
Blue (RAL5015)
%
Polycarbonate, reinforced with 10 % fiberglass.
mm
L x W x H (295 x 151 x 75)
kg
Approx. 1.6
Test
(Conducted emission) 10 kHz – 30 MHz, class A
(Radiated emission) 30 MHz – 1 GHz
(Conducted emission) 10 kHz – 30 MHz (type test)
(Radiated emission) 150 kHz – 2 GHz (type test)
(ESD interference immunity) ±8 kV
(Radiated interference immunity) 80 MHz – 2 GHz
(Burst interference immunity) ±2 kV
(Surge interference immunity) ±1 kV/±2 kV
(Surge interference immunity) ±1.8 kV
(LF line-related interference) 0.03 – 10 kHz/3 Veff
(Line fluctuations/STANAG 1008)
(Dielectric strength) 550 VAC/10 mA
(Isolation) 500 V/10 Mohm
. Cable length shall not exceed 10 cm.