Fault
Alarm text
code
363
STOP POWER
STAGE 1
364
STOP POWER
STAGE 2
365
STOP MV-WIR‐
ING
381
TRAN.OUT1
PLANT DEF
382
TRAN.OUT2
PLANT DEF
383
TRAN.OUT3
PLANT DEF
384
TRAN.OUT4
PLANT DEF
385
TRAN.OUT5
PLANT DEF
386
TRAN.OUT6
PLANT DEF
Meaning
Solenoid valve or wiring or
ECU defective
automatic engine shutdown
Solenoid valve or wiring or
ECU defective
automatic engine shutdown
Solenoid-valve wiring faulty;
automatic engine shutdown
Binary transistor output
plant 1 defective
Binary transistor output
plant 2 defective
Binary transistor output
plant 3 defective
Binary transistor output
plant 4 defective
Binary transistor output
plant 5 defective
Binary transistor output
plant 6 defective
Task
1. Check wiring.
2. Try to re-start the engine
(→ Page 52).
3. Contact Service.
1. Check wiring.
2. Try to re-start the engine
(→ Page 52).
3. Contact Service.
1. Check wiring.
2. Try to re-start the engine
(→ Page 52).
3. Contact Service.
Contact Service.
Contact Service.
Contact Service.
Contact Service.
Contact Service.
Contact Service.
MS150025/02E 2012-10 | Troubleshooting | 83