MTU 12 V 2000 P12 Operating Instructions Manual page 27

Diesel engine
Table of Contents

Advertisement

Operating voltage
Power consumption
Heat loss
Operating temperature range
Storage temperature range
Relative air humidity
Degree of protection
Shock
Vibration
EMC
Rated voltage: 24 VDC
Continuous voltage:
16.5 VDC to 32 VDC
Temporarily restricted operation:
11 VDC to 36 VDC
Residual ripple: Max. 8 V
Max. 30 A
Max. 35 W
0 °C to +75 °C
–10 °C to +75 °C
0% to 95 % condensing
IP 65 DIN 40 050
15 g/11 ms semi-sinusoidal shock
2 Hz to 13 Hz: X
= ±1.6 mm
pp
25 Hz to 100 Hz: a= ±4 g
100 Hz to 2000 Hz: Electrical noise 1.3 g rms
DIN EN 50081–2
DIN EN 50082–2
IEC 1000–4–2
IEC 1000–4–3
IEC 1000–4–4
IEC 1000–4–5
IEC 1000–4–6
MS150025/02E 2012-10 | General Information | 27
pp

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

16 v 2000 p12

Table of Contents