Cylinder Liner; Cylinder Liner - Endoscopic Examination - MTU 12 V 2000 P12 Operating Instructions Manual

Diesel engine
Table of Contents

Advertisement

7.2 Cylinder Liner

7.2.1 Cylinder liner – Endoscopic examination
Preconditions
☑ Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Rigid endoscope
Preparatory steps
1.
Remove cylinder head cover (→ Page 97).
2.
Remove injector (→ Page 103).
Positioning crankshaft at BDC
1.
Using barring gear, turn crankshaft until crankshaft journal of the cylinder to be inspected has reached
BDC.
2.
Insert endoscope into cylinder liner through injector seat.
Cylinder liner – Endoscopic examination
Findings
• Thin carbon coating on circumference of carbon scraper ring
• Slight localized additive deposits at top edge
• Singular smooth areas at lower edge
• Carbon deposits on circumference in clearance between top piston
ring and bottom edge of carbon scraper ring
• First signs of marks left by top piston ring
• Bright mark on entire circumference
• Consistent honing pattern without objections
• First signs of marks left by lower cooling bores
• Running pattern seems darker
• Dark areas with even or varying degrees of discoloration
• Beginning and end of the discoloration are not sharply defined and
do not cover the entire stroke area
• Dark areas in the upper section of the cooling bore, remaining cir‐
cumference without objections
• Piston rings without objections
• On the entire circumference, apart from light areas of discoloration
(that do not impair operation) clearly darker stripes that start at the
top piston ring
• Heat discoloration in the direction of stroke and honing pattern dam‐
age
• Heat discoloration of piston rings
1.
Compile endoscopy report using the table.
2.
Use technical terms for description of the liner surface (→ Page 89).
3.
Depending on findings:
• do not take any action or
• carry out a further endoscopic examination as part of maintenance work or
• contact Service; cylinder liner must be replaced.
Part No.
Y20097353
Action
No action required
Further endoscopic examina‐
tion required as part of main‐
tenance work
Cylinder liner must be re‐
placed; Service must be con‐
tacted
MS150025/02E 2012-10 | Task Description | 87
Qty.
1