2.6 Peripheral Interface Modules (PIMs)

PIMs for use with processor printed circuit board MPU 23 and MPU 27
PIM design
1 Module cassette 1
2 Basic module 1
3 Printed circuit board
PIM 601/602 comprises:
• Module cassette 1 (1) to accommodate one MPU 23, MPU 27 and one PIM printed circuit board.
• Basic module 1 (2) with printed circuit board COB 1-0X (3).
• Printed Circuit Board SCB 3
Slots and terminals
1 Slot 1
2 Slot 2
Slot 1 is reserved for the microprocessor card (MPU 23 and MPU 27). All other slots may be populated
with PIM printed circuit boards.
Example: The "n" in "n09" stands for the slot and "09" designates the terminal. "209" means: Slot 2, ter‐
minal 9.
MS150025/02E 2012-10 | General Information | 33