1.7 Operation by PLC function (Pr. 414, Pr. 415,
Pr. 498, Pr. 506 to Pr. 515, Pr. 826 to Pr. 865)
I/O data read, write, etc. can be performed by accessing the inverter in the
predetermined method using special relays, special registers, etc.
Operation, parameter read/write, etc. can be performed in accordance with the
created sequence programs (built in the inverter) using input data from the
control input terminals.
With the output signals, output data can be output to outside the inverter from
the control output terminals as not only the inverter's status signals but also pilot
lamp on/off, interlock and other control signals set freely by the user.
Parameter
Number
414
PLC function operation selection
415
Inverter operation lock mode setting
498
PLC function flash memory clear
506 to 515 Parameter 1 to 10 for user
826 to 865 Parameter 11 to 50 for user
Name
Operation by PLC function (Pr. 414, Pr. 415,
Pr. 498, Pr. 506 to Pr. 515, Pr. 826 to Pr. 865)
Initial
Setting
Value
Range
0
0, 1
0
0, 1
0
0 to 9999
0
0 to 65535
Refer to
Page
9
49
50
15
1
7