Setting List Of Built-In Plc Function Parameter - Mitsubishi Electric FR - F700 Programming Manual

Plc function programming manual
Table of Contents

Advertisement

Prior to sequence program creation
1.8.6

Setting list of built-in PLC function parameter

The built-in PLC function parameters are designed to specify the ranges of using the
PLC function, e.g. program capacity, device assignment and various functions.
Item
Sequence program
capacity
File register capacity
Comment capacity
Status latch
Sampling trace
Microcomputer program
capacity
Latch range setting
Link range setting
I/O assignment
Internal relay, latch relay,
step relay setting
Watchdog timer setting
Timer setting
Counter setting
Remote run/pause
Error-time operation mode
STOP → RUN output mode
Print title registration
Keyword registration
REMARKS
•The following functions are not supported.
1. Constant scan, 2. Latch (device data backup for power failure), 3. Pause,
4. Status latch, 5. Sampling trace, 6. Offline switch
•If parameter clear of the inverter is performed, the above built-in PLC function parameters are
not cleared.
•For the built-in PLC function parameter setting operation, refer to the GX Developer
Operating Manual.
12
GX Developer Default
6k steps
None
None
None
None
None
L1000 to L2047
None
None
M0 to 999
L1000 to 2047
None for S
200ms
100ms: T0 to 199
10ms: T200 to 255
(100ms timers since only T0 to 7
are available)
Without interrupt counters
None
Fuse blow: Continued
I/O verify error: Stop
Operation error: Continued
Special function module check
error: Stop
Operation status prior to
STOP is re-output.
None
None
Setting Range
<Usable device range>
4k step
Cannot be set (default)
Cannot be set (default)
Cannot be set (default)
Cannot be set (default)
Cannot be set (default)
Cannot be set (invalid if set)
Cannot be set (default)
Cannot be set (default)
L and S cannot be set.
(Operates as M if set)
<M0 to M63>
10 to 2000ms
16 points for 100ms, 10ms and
retentive timers. Timers have
consecutive numbers.
<T0 to T15>
Cannot be set (default)
<C0 to C15>
Can be set using X0 to X3F.
Otherwise invalid. Pause does not
function.
Setting invalid (since there are no
fuses)
Setting invalid
(since there are no I/O modules)
Stop/Continued
Setting invalid (since there are no
special modules)
Prior to STOP/after operation
execution
Cannot be set
Online setting cannot be made but
parameter setting is valid.