Output Instructions : Bit Device, Timer, Counter - Mitsubishi Electric FR - F700 Programming Manual

Plc function programming manual
Table of Contents

Advertisement

3.25.4 Output instructions : bit device, timer, counter ... OUT
Bit devices
X
Bit device
Device
Timer
Setting
Device
Counter
Setting
OUT
(Y, M)
OUT
(T)
OUT
(C)
Functions
OUT (Y, M)
(1) Outputs the operation result up to OUT instruction to the specified device.
Operation Result
OFF
ON
REMARKS
Three steps are used for the OUT instruction only when the following device is used.
Special relay (M)
Usable Devices
Word (16-bit)
devices
Y
M
T
C
OUT Instruction
Coil
OFF
ON
Constants Level
D
K
H
Y15
Device number
K50
Setting Any of 1 to 32767 is
T0
Setting Any of data register
D10
T0
Setting Any of 1 to 32767 is
K50
C0
Setting Any of data register
D10
C1
Contacts
N/O contact
Not energize
Energize
Sequence instructions
Error
Flag
Digit
Designation
(M9010,
N
M9011)
valid
Device number (T0 to 15)
contents 1 to 32767
is valid
Device number (T0 to 15)
valid
Device number (C0 to 15)
contents 1 to 32767
is valid
Device number (C0 to 15)
N/C contact
Energize
Not energize
3
131