1.4 PLC function specifications

The following table indicates the program capacity and devices of the PLC function.
Control method
I/O control method
Programming language
PLC instructions
Basic instructions
Application instructions
Processing speed
Number of I/O points
Number of analog I/O points
Watchdog timer
Memory capacity
Program capacity
Internal relay (M)
Latch relay (L)
Step relay (S)
Link relay (B)
Timer (T)
Counter (C)
Data device (D)
Link register (W)
Annunciator (F)
File register (R)
Accumulator (A)
Index register (Z, V)
Pointer (P)
Interrupt pointer (I)
Special relay (M)
Special register (D)
*1 As inverter control is also performed actually, the scan time is approximately 40ms at 500 steps.
*2 These signals use the same terminals as used by the input and output signals given in the
common specifications of the inverter.
One point is always necessary for a sequence start (RUN/STOP).
*3 Function to latch a device at power failure is not provided.
Therefore, select EEPROM for storage using
(D110 to D159) to hold device values.
REMARKS
•No buffer memory is available.
4
Repeated operation (by stored program)
Refresh
Relay symbolic language (ladder mode)
Logic symbolic language (list mode)
23
64
20
PLC instruction: 1.9μs to 12μs/step(*1)
128 (X: 64 points, Y: 64 points)
19 points installed, X: 12 points, Y: 7 points(*2)
FR-A7AX, X: 16 points
FR-A7AY, Y: 6 points
FR-A7AR, Y: 3 points
5 points installed, Input: 3 points, Output: 2 points
FR-A7AY output: 2 points
10 to 2000(ms)
6k bytes used by sequence and parameters.
4k step (Can be edited from 0 to 4094 steps.)
64(M0 to M63)
None (Can be set with parameters but will not latch) (*3)
None (Can be set with parameters but will operate as M)
None
Points
16
100ms timer: Set time 0.1 to 3276.7s (T0 to T15)
Specifications
10ms timer: Set time 0.01 to 327.67s
100ms retentive timer: Set time 0.1 to 3276.7s
Points
16
Normal counter: Setting range 1 to 32767 (C0 to C15)
Specifications
Interrupt program counter: None
160(D0 to D159)
None
None
None
None
None
None
None
256 (M9000 to 9255) with function limit
256 (D9000 to 9255) with function limit
(Refer to page 44.)
F700 Sequence Section
Pr.506 to Pr.515, Pr.826 to Pr.865
User parameter