("n" indicates a value determined according to the station number setting.)
*1
Signal names are initial values. Using Pr. 180 to Pr. 186, Pr. 188, and Pr .189, you can
change input signal functions.
Signals of the RYn0, RYn1, and RYn9 can not be changed. Even when changed using Pr.
178, Pr. 179, and Pr. 187, the settings are invalid.
Refer to the Inverter Manual for details of Pr. 178 to Pr.189.
*2
Signal names are initial values. Using Pr. 190 to Pr .196, you can change output signal
functions.
Refer to the Inverter Manual for details of Pr. 190 to Pr.196.
(2) Remote register
PLC Function
Address
Device No.
RWwn
RWwn+1
RWwn+2
RWwn+3
D9062
RWwn+4 Registers designed to
D9063
RWwn+5
D9064
RWwn+6
D9065
RWwn+7
("n" indicates a value determined according to the station number setting.)
Description
Upper 8
Lower 8
Bits
Bits
Monitor
Monitor
code 2
code 1
Set frequency (0.01Hz
increments)
Link
Instruction
parameter
expansion
code
setting
Write data
read data received
from the master
station
CC-Link I/O specifications
PLC Function
Address
Device No.
RWrn
RWrn+1
RWrn+2
RWrn+3
D9078
RWrn+4
D9079
RWrn+5
D9080
RWrn+6
D9081
RWrn+7
Description
First monitor value
Second monitor
value
Reply
Reply
code2
code1
Read data
Registers designed
to write data to be
sent to the master
station.