Description of devices

3.9 Description of devices
3.9.1

Device list

The following table indicates the device names usable with the built-in PLC function
and their ranges of use.
Input (X)
Output (Y)
Internal relay (M)
Latch relay (L)
Step relay (S)
Link relay (B)
Timer (T)
Counter (C)
Data device (D)
Link register (W)
Annunciator (F)
File register (R)
Accumulator (A)
Index register (Z, V)
Pointer (P)
Interrupt pointer (I)
Special relay (M)
Special register (D)
82
Table 3.3 Device List
64 (X0 to X3F) <12 points installed>
64 (Y0 to Y3F) <7 points installed>
64 (M0 to M63)
None (Can be set with built-in PLC function parameters
but will not latch)
None (Can be set with built-in PLC function parameters
but will operate as M)
None
Points
16(T0 to T15)
100ms timer: Set time 0.1 to 3276.7s
Specifications
10ms timer: Set time 0.01 to 327.67s
100ms retentive timer: Set time 0.1 to 3276.7s
Points
16(C0 to C15)
Normal counter: Setting range 1 to 32767
Specifications
Interrupt program counter: None
160(D0 to D159)
None
None
None
None
None
None
None
256 (M9000 to M9255) with function limit
256 (D9000 to D9255) with function limit