Mitsubishi Electric FR - F700 Programming Manual page 204

Plc function programming manual
Table of Contents

Advertisement

(4) Number of selectable items
Set data
Monitor (Refer to page 194.)
Fault (Refer to page 195.)
Parameter (Refer to page 196.)
*
If a set data is set exceeding the number of selectable items, the calculation error
(error code 50) occurs at execution of the setting.
If a value other than "01 to 03" is set in the lower 8 bits of
error (error code 50) occurs.
CAUTION
•If the data is larger than the storable size of the applicable devices, the
exceeded data will modify other devices although no error will occur. Before
storing data, make sure to have enough devices available to store the data.
REMARKS
• Do not change the data in each device while it is being displayed. The data in the device is
used for actual communication. If data is changed while it is being displayed, the data to be
transmitted also changes. The device number, where the first character of the set data is set,
is registered in the inverter.
• The characters other than ASCII data 0x20 to 0x7A, which can be displayed on FR-PU07-01,
are replaced by 0x20 (spaces).
• The following characters cannot be displayed on FR-PU07-01: [ ^ ] (H5E), [ _ ] (H5F), and [ ' ]
(H60).
Execution Conditions
See below for the execution conditions of the PR command.
ASCII print command
PR
Number of
selectable items
Up to 3 items
Up to 5 items
Up to 10 items
ON
ON
OFF
OFF
Executed only once
Display command
+0, the calculation
S