Mitsubishi Electric FR - F700 Programming Manual page 28

Plc function programming manual
Table of Contents

Advertisement

Number
Name
Option output
D9207
terminal status
PTC thermistor
D9211
resistance
PID measured
D9213
value 2
D9214
User defined fault
Monitor setting
D9215
selection
Monitor 1 setting The PR command changes the first monitor to the
D9216
D9217
Monitor 2 setting
D9218
Monitor 3 setting
32-bit cumulative
D9224
power
(lower 16-bit)
32-bit cumulative
D9225
power
(upper 16-bit)
32-bit cumulative
D9226
power
(lower 16-bit)
32-bit cumulative
D9227
power
(upper 16-bit)
BACnet reception
D9228
status
* The setting depends on the inverter capacities.
(FR-F720-02330-NA (FR-F740-01160-NA/EC) or lower/FR-F720-03160-NA (FR-F740-01800-NA/EC) or
higher)
Description
The output status of the FR-A7AY, FR-A7AR is stored.
All off (0) when an option is not fitted.
B15
B12B11
Stores the PTC thermistor resistance at terminal 2
when PTC thermistor protection is active.
(0.10kΩ increments)
Stores the PID measured value (0.1% increments)
(Monitoring is available even when PID control is not
active.)
An inverter fault can be initiated by setting a value
between 16 and 20 in D9214.
Set D9215 to display the monitored values, which are
set by D9216 to D9218, with decimal points.
D9216 monitor on FR-PU07-01.
The PR command changes the second monitor to the
D9217 monitor on FR-PU07-01.
The PR command changes the third monitor to the
D9218 monitor on FR-PU07-01.
1kWh
1kWh
0.01kWh/0.1kWh *
0.01kWh/0.1kWh *
Displays BACnet reception status
B8B7
B4B3
B0
0:OFF
1:ON
Y0
Y1
Y2
Y3
Y4
Y5
Y6
RA1
RA2
RA3
Device map
Page
38
39
39
39
39
1
21

Hide quick links: