WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Remove the top cover and the control as-
sembly (see page 4-2 for the procedures).
Flowmeter
REMOVING THE FLOWMETER
4.
Loosen the two clamps and remove the two
hoses from the ends of the flowmeter.
5.
Disconnect the wire connector from the
flowmeter.
6.
Squeeze the locking tabs on the mounting
post and remove the flowmeter from the
bracket.
Wire Connector
4-9
Flowmeter
Mounting Post