4.1.6 Operating and Changing the Electronic Lock

Before operating the lock or changing the combination,
READ THE INSTRUCTIONS THOROUGHLY
.
*
*See manufacturers lock manual included in the "Open Me First Box"
The LA GARD "LG Basic" series electronic lock uses a touch key
pad for all lock functions.
Power is supplied to the lock via a standard 9-volt Alkaline
battery which contained within the external portion of the lock.
The lock will warn of low voltage by repeatedly beeping.
TO UNLOCK FROM DEFAULT COMBINATION
Step 1
Press the default combination one button at a time, (see lock manual or consult your dealer for
default combination). A beep is heard following each key press.
Step 2
If the combination is entered correctly a double-beep is heard and the internal lock solenoid will
click indicating that the lock is open and the vault handle my now turn.
Step 3
If the wrong combination is entered a triple-beep will be heard. If the correct combination is not
entered within 4 consecutive attempts a 5 minute delay or "lock out" will begin. During this time,
the led at the 2 o'clock position on the face of the lock will flash at 10 second intervals. In
addition any key press will respond with a triple-beep. Once the 5 minutes has elapsed, 2 more
consecutive failed attempts will restart the 5 minute timer.
WARNING: While orienting yourself with the lock, making changes to the lock programming
(including changing the combination) ALWAYS work with the vault door open. Do not close the
vault until the lock has been thoroughly tested.
Genmega does NOT program a master combination!