2. Periodical check
[2]
13. Repeat steps 1 to 12 similarly for the paper feed tray 5.
2.1.3
Replacing the pick-up roller
A. Periodically replaced parts/cycle
• Pick-up roller: Every 300,000 prints
NOTE
• Replace the separation roller assy, feed roller and pick-up roller at the same time.
B. Replacing procedure
1. Remove the rear right cover. (Remove the right lower cover for 4th row.)
See P.13
2. Remove the paper feed tray 4. (Remove the paper feed tray 5 from 4th row.)
3. Remove the separation roller mounting bracket assy.
See the procedures 1 to 3 in P.3 "Replacing the separation roller assy."
8
Confidential – for internal use only, do not distribute
12. Remove the C-ring [1] and remove
[1]
A093F2C531DA
4. Disconnect the connector [1] and
[2]
[1]
A093F2C018DA
Field Service Ver. 1.0 Oct. 2007
the feed roller [2].
remove the harness from two wire
saddles [2].