7. Trouble code
7.3
Solution
7.3.1
C0001: LCT communication error
PC control board (PCCB)
Step
Turn OFF the power switch, wait for 10 sec.
1
or more, and turn ON the power switch.
2
PCCB replacement
7.3.2
C0209: LCT elevator motor failure
Elevator motor (M5)
Elevator motor pulse sensor (PS10)
Step
Check the motor and sensor connectors for
1
proper connection, and correct as neces-
sary.
Check the connector of motor for proper
2
drive coupling, and correct as necessary.
3
PS10 I/O check
4
M5 operation check
5
REYB replacement
6
PCCB replacement
34
Confidential – for internal use only, do not distribute
Relevant electrical parts
Action
Relevant electrical parts
Action
Field Service Ver. 1.0 Oct. 2007
WIRING DIAGRAM
Control signal
—
—
Relay board (REYB)
PC control board (PCCB)
WIRING DIAGRAM
Control signal
—
—
REYB PJ2REYB<A>-5 (ON)
REYB PJ2REYB<B>-6 to 7
—
—
Location
(Electrical
components)
—
—
Location
(Electrical
components)
—
—
PC-406 K-5
PC-406 K-6 to 7
—
—