Cleaning Procedure; Transfer Belt Unit; Ph Window Y,M,C,K - Konica Minolta Magicolor 8650 Service Manual

Konica minolta magicolor 8650 laser printer service manual
Hide thumbs Also See for Magicolor 8650:
Table of Contents

Advertisement

Field Service Ver. 2.0 Nov. 2007
6.4

Cleaning procedure

NOTE
• The alcohol described in the cleaning procedure represents the ethanol isopropyl
alcohol.
6.4.1

Transfer belt unit

1. Remove the transfer belt unit.
See P.37
[1]
6.4.2

PH window Y,M,C,K

1. Open the front door.
[1]
[2]
[1]
Confidential – for internal use only, do not distribute
2. Using a cleaning pad, wipe the trans-
NOTE
• Do not wipe out with water.
• Do not wipe out with any solvents.
A02EF2C207DA
2. Remove the PH window cleaning jig
A02EF2C502DA
3. Insert the PH window cleaning jig [1]
NOTE
• Clean every PH window of Y,M,C,K.
A02EF2C219DA
fer belt [1].
[1] from the front door.
to the cleaning port [2] and clean it
by putting the jig back and forth a
couple times.