14. Mechanical adjustment
14. Mechanical adjustment
14.1 Mechanical adjustment of the scanner section
14.1.1
Adjustment of the scanner motor belt
This adjustment must be made in the following case:
• The scanner motor assy has been removed.
• The scanner drive cables have been rewound.
[2]
[2]
[1]
[4]
[4]
452
[1]
[2]
A00JF3C538DA
[3]
[2]
[4]
A00JF3C526DA
Field Service Ver. 4.0 Jun. 2008
1. Temporarily secure the scanner
motor assy [1] with three screws [2].
2. With the scanner drive gear set
screw [1] located on the right-hand
side as shown on the left, slide the
scanner motor assy [2] to the left and
check that it is returned to the origi-
nal position by the tension of the
spring [3].
Perform this step three times.
3. Tighten the three screws [4] to fix the
scanner motor assy into position.