Field Service Ver. 4.0 Jun. 2008
Error code
Control panel
Error concerning the network
0x00111000
• Connection has been completed.
Error concerning the network
0x00111001
• It cannot be connected to the server.
Error concerning the network
0x00111100
• Communication timeout.
Error concerning the network
0x00111101
• Disconnection occurred
Error concerning the network
0x00111110
• The network is not connected.
Error concerning the network
0x00110010
• Others
FTP error
0x00001###
• Reply code when it failed to be con-
nected
FTP error
0x00002###
• Error reply code for the user command
or pass command
FTP error
0x00003###
• Error reply code for CWD command
FTP error
0x00004###
• Error reply code for the TYPE com-
mand.
FTP error
0x00005###
• Error reply code for the PORT com-
mand.
FTP error
0x00006###
• Error reply code for the PASV com-
mand.
FTP error
0x00007###
• Error rely code for the RETR com-
mand.
• It cannot be accepted because of the
0x1000 0100
job currently being executed.
• ISW being executed by other method.
• It cannot be accepted because the sub
0x10000101
power switch is OFF.
• The Internet ISW is already being exe-
0x10000102
cuted.
Description
5. Firmware upgrade
Countermeasure
• Check the User's network environment.
(LAN cable's connection)
• Check the status of the following set-
ting.
[Service Mode] → [Internet ISW] →
[Forwarding Access Setting]
• Check to see if the FTP server oper-
ates normally.
• Check the network environment of the
User.
• Check to see if the FTP server oper-
ates normally.
• Check the network environment of the
User.
• Check to see if the FTP server oper-
ates normally.
• Check to see if FTP server normally
operates.
• Check the IP address, user's name,
etc.
• Check to see if FTP server operates
normally.
• Check to see if FTP server operates
normally.
• Check to see if FTP server operates
normally.
• Set the PASV mode to "OFF", and try it
again.
• Check to see if FTP server operates
normally.
• Wait for about 30 minutes and try it
again.
• Wait for the current job to be completed
and try it again.
• Turn sub power switch ON and try it
again.
• Wait for the current Internet ISW to be
completed.