8. Trouble code
8.3

Solution

8.3.1

C0001: LCT communication error

PC control board (PCCB)
Step
Turn OFF the main power switch, wait for
1
10 sec. or more, and turn ON the main
power switch.
2
PCCB replacement
8.3.2

C0209: LCT elevator motor failure

Elevator motor (M5)
Elevator motor pulse sensor (PS10)
2
Step
Check the motor and sensor connectors for
1
proper connection, and correct as neces-
sary.
Check the connector of motor for proper
2
drive coupling, and correct as necessary.
3
PS10 I/O check, sensor check
4
M5 operation check
5
REYB replacement
6
PCCB replacement
36
2
Relevant electrical parts
Action
Relevant electrical parts
Action
Field Service Ver. 3.0 Jan. 2008
WIRING DIAGRAM
Control signal
Relay board (REYB)
PC control board (PCCB)
WIRING DIAGRAM
Control signal
REYB PJ2<A>-5 (ON)
REYB PJ2<B>-6 to 7
Location
(Electrical
components)
Location
(Electrical
components)
PC-405 K-5
PC-405 K-6 to 7