n n
Reassembling Notes
•
Route the panel-main harness and CCD HP sensor harness through the three notches, then
tape them as illustrated on the previous page.
•
When replacing the CCD flat cable with a new one, be sure to arrange the new cable as
illustrated below, then route it along the positioning rib as shown on the previous page.
•
Set the CCD motor back into place with its connector side facing up as shown on page IV-28.
•
Set the CCD lock in the release (forward) position. If the CCD lock is placed in the lock
position, the CCD home positioning will fail in the next powering-up sequence. If this happens,
turn the CCD lock to the release position.