Selector
No.
1
Min. OFF time length of calling
signal (Ci)
2
3
Max. OFF time length of calling
signal (Ci)
4
5
Detecting time setting
6
7
Delay
8
Not used.
Selectors 1 through 4: Min. and max. OFF time length of calling signal (Ci)
l
If the equipment detects the OFF state of calling signal (Ci) for a time length which is greater than
the value set by selectors 1 and 2 and less than the value set by selectors 3 and 4, it interprets the
Ci signal as OFF.
Selectors 5 and 6: Detecting time setting
l
These selectors set the time length required to make the equipment acknowledge itself to be
called. That is, if the equipment continuously detects calling signals with the frequency set by
selectors 1 through 4 of WSW14 during the time length set by these selectors 5 and 6,
acknowledges the call.
Selector 7:
Delay
l
Setting this selector to "0" allows the equipment to insert a 900 ms WAIT after acknowledgment of
the call until the equipment turns on the CML relay to start receiving operation.
WSW12
(Signal detection condition setting)
Function
V - 24
Setting and Specifications
No. 1
2
0
0
:
300 ms
1500 ms
0
1
:
500 ms
1
0
:
700 ms
1
1
:
900 ms
No. 3
4
0
0
:
6 sec.
0
1
:
7 sec.
1
0
:
9 sec.
1
1
:
11 sec.
No. 5
6
0
0
:
800 ms (1000 ms*)
0
1
:
200 ms
1
0
:
250 ms
1
1
:
150 ms
0:
Yes
*1000 ms in Chinese versions.
(in the U.S.A. and
Canadian versions)
(in other versions)
1:
No
it