Selector
No.
1
ECP mode*
Recovery from Inactive PC
2
Interface
3
PC Power-off Recognition Time
4
Not used.
5
6
Lower limit of frequency to be
|
ignored after detection of calling
8
signals (Ci)
Selector 1:
ECP mode
l
The ECP mode enhances the normal bidirectional communications between the facsimile
equipment and the connected PC for higher transmission speed.
Selector 2:
Recovery from Inactive PC Interface
l
If the facsimile equipment recognizes via the STB signal line that the connected PC is powered
off, it will turn the PC interface outputs Low to protect the PC from hazards that could be caused
by weak electric current accidentally flown from the equipment.
This selector determines whether the equipment should recover from the inactive PC interface to
normal interfacing state upon receipt of data from the PC.
l
Selector 3:
PC Power-off Recognition Time
This selector sets the time length from when the equipment detects the PC powered off until it
recognizes the detected state as power-off.
If selector 2 is set to "0," it is recommended that selector 3 be set to "1"; otherwise, the equipment
may mistakenly detect PC powered off.
Selectors 6 through 8: Lower limit of frequency to be ignored after detection of calling signals (Ci)
l
At the start of reception, if the equipment detects the frequency of calling signals (Ci) specified by
selectors 1 through 4 of WSW14, it will start the ringer sounding. When doing so, the equipment
may fail to detect the calling signals normally due to noises superimposed at the time of reception.
To prevent it, use selectors 6 through 8 of WSW36.
If the equipment detects higher frequencies than the lower limit specified by these selectors, it will
regard them as noise and interpret that detecting state as being normal, allowing the ringer to keep
sounding (until the equipment starts automatic reception of FAX data if in the FAX mode,
according to the preset number of ringers).
WSW36
(Function setting 14)
Function
V - 44
Setting and Specifications
0: ON
1:
0: Disabled
1:
0: Normal
1:
No. 6 7 8
0 0 0 :
0 (Not ignored)
0 0 1 :
4 (448 Hz)
0 1 0 :
8 (244 Hz)
0 1 1 :
12 (162 Hz)
1 0 0 :
16 (122 Hz)
1 0 1 :
20 (97 Hz)
1 1 0 :
24 (81 Hz)
1 1 1 :
28 (69 Hz)