Brother MFC9100C Service Manual page 147

Facsimile equipment
Hide thumbs Also See for MFC9100C:
Table of Contents

Advertisement

Selector
No.
1
|
1st dial tone detection time
length
3
4
Time-out length for 1st and 2nd
dial tone detection
5
6
Detection level of 1st dial tone
|
and busy tone before dialing
8
NOTE: The WSW08 is not applicable in those countries where no dial tone detection is supported,
e.g., U.S.A.
Selectors 1 through 3: 1st dial tone detection time length
l
Upon detection of the 1st dial tone for the time length set by these selectors, the equipment starts
dialing.
This setting is effective only when selectors 1 through 3 of WSW05 are set to "1,1,1."
Selectors 4 and 5: Time-out length for 1st and 2nd dial tone detection
l
These selectors set the time-out length for the 1st and 2nd dial tone detection so that the
equipment waits dial tone input for the specified time length and disconnects itself from the line
when no dial tone is inputted.
WSW08
(Dial tone setting 2)
Function
V - 20
Setting and Specifications
No. 1 2 3
0 0 0 :
50 ms
0 0 1 :
210 ms
0 1 0 :
500 ms
0 1 1 :
800 ms
1 0 0 :
900 ms
1 0 1 :
1.5 sec.
1 1 0 :
2.0 sec.
1 1 1 :
2.5 sec.
No. 4 5
0 0 : 10 sec.
0 1 : 20 sec.
1 0 : 15 sec.
1 1 : 30 sec.
No. 6 7 8
0 0 0
:
0 0 1
:
0 1 0
:
0 1 1
:
1 0 0
:
1 0 1
:
1 1 0
:
1 1 1
:
-21 dBm
-24 dBm
-27 dBm
-30 dBm
-33 dBm
-36 dBm
-39 dBm
-42 dBm

Hide quick links: