Environmental Requirements - Sun Oracle Fire X4170 M2 Installation Manual

Servers
Table of Contents

Advertisement

TABLE 1-5
Parameter
Maximum current AC RMS
AC operating range
Output
3.3 VDC STBY
+12 VDC
Power dissipation
Max power consumption
Max heat output
Volt-Ampere rating
Sun Fire X4270 M2 Server
Input
Nominal frequencies
Nominal voltage range
Maximum current AC RMS
AC operating range
Output
3.3 VDC STBY
+12 VDC
Power dissipation
Max power consumption
Max heat output
Volt-Ampere rating

Environmental Requirements

TABLE 1-6
M2 Servers.
14
Sun Fire X4170 M2 and X4270 M2 Servers Installation Guide • January 2012
Servers Electrical Specifications (Continued)
lists the environmental requirements for the Sun Fire X4170 M2 and X4270
Value
9.0 amps Max
90-264 VAC
3.6A
62.3 A
873 W
2977 BTU/hr
891 VA @ 240 VAC, 0.98 P.F.
50/60 Hz
100 VAC, 110-127 VAC, 200-240 VAC
13.0 amps Max
90-264 VAC
3.0 A
86.7 A
1235.3 W
4212 BTU/hr
1261 VA @ 240 VAC, 0.98 P.F.