Environmental Requirements
TABLE 1-5
TABLE 1-5
Parameter
Operating temperature
(single, non-rack system)
Non-operating temperature
(single, non-rack system)
Operating humidity
(single, non-rack system)
Non-operating humidity
(single, non-rack system)
Operating altitude
(single, non-rack system)
Non-operating altitude
(single, non-rack system)
Managing Your Server
After you have installed your server, you have several different options for
managing it depending on your situation.
Managing many servers
■
Your server can be managed with a wide variety of system management tools. For
more information on the system management tools, see the information at
(http://www.oracle.com/goto/system-management)
Here is a sampling of some of these tools:
■
10
Sun Fire X4470 Server Installation Guide • April 2011
lists the environmental requirements for the Sun Fire X4470 Server.
Server Environmental Requirements
Value
5
-40
10% to 90% relative humidity, non-condensing
Up to 93% relative humidity, non-condensing
Up to 3048 m, maximum ambient temperature is derated by 1
degree C per 300 m above 900 m
Up to 12,000 m
If your server is one of many x86 and SPARC servers that you want to manage
from a single interface, you can use the Oracle Enterprise Manager Ops Center.
For more details, see
(http://www.oracle.com/us/products/enterprise-
manager/opscenter/index.html)
°
°
°
°
C to 35
C (41
F to 95
°
°
°
C to 70
C (-40
F to 158
F)
°
F)