Status Indicator RAPs
11 No Power RAP
Description
When system power is turned on the LCD panel does not come on.
Check and Cause
1. Check fuses on SMPS,
2. Check if the power input and SMPS output
are normal.
3. LCD panel does not come on but normal
start up sounds are heard.
4. After replacing OPE unit display does not
come on and no start up sounds are heard.
2-14
PL
1.
1. Install new fuses or SMPS,
sary.
2. Replace the power supply cord or SMPS,
PL
1. Check power fuse and SMPS fuses.
Replace if necessary,
3. Replace the OPE unit,
4. Replace the Main PBA,
11/05
Solution
PL
1, as neces-
PL
1.
PL
5.
PL
1.
Workcentre PE 220