Xerox WORKCENTRE PE 220 Service Manual page 152

Workcentre
Hide thumbs Also See for WORKCENTRE PE 220:
Table of Contents

Advertisement

General Procedures and Information
Detail Description (Engine Test Mode)
01.Motor Test
02.Pick Up Test
03.Fan Test
04.Manual Clutch
Test
05.PTL Test
11.LSU Motor
12.LSU Hsync Test
13.LD Test
21.Feed Sen Test
22.Exit Sen Test
23.Cover Sen Test
24.Empty Sen Test
25.Manual Sen Test
31.Them ADC 180
32.Them ADC 140
33.Them ADC 120
34.Them ADC 100
41.MHV Test
42.Dev Bias Test
43.THV EN/NEG
Test
44.THV ON(1300V)
45.THV ADC 1300V
46.THV ADC
600V~3500
6-44
The main motor starts when the execution key is pressed
and stops when the stop key is pressed.
Automatically stops, when the execution is chosen.
stops, when the execution is chosen.
The fan starts when the execution key is pressed and
stops when the stop key is pressed.
The tray2,3 clutch is on for 1sec and then it automatically
stops, when the execution is chosen.On this function,
the main motor runs before 2sec from the point of the
clutch
on in order to check the clutch state.
PTL (Pre-Transfer Lamp) is lights when the execution key
chosen and it stops when the stop key is chosen.
The laser motor starts when the execution key is pressed
and stops when the stop key is pressed.
The LSU motor starts and "Laser Ready" is displayed if
the motor spins at the correct speed, otherwise "Laser
Error" is displayed.
"Diode On" is displayed, when the laser diode is on.
Otherwise "Diode Off" is displayed.
These functions allow the current state of the sensor to be
displayed.
This function allows the current state of the Cover sensor
to be displayed. Touch the sensor and confirm that the
message changes: "Cover Open" to "Cover Close"
These functions allow the current state of the sensor to be
displayed.
"Current value" is displayed on the upper line of the LCD,
and "Target value" on the bottom line.
Target value is limited from "191°C" to "80°C"
These Functions are provided to check whether the
control of the HVPS is functioning correctly.
Table 1:
11/05
Main Motor On/Off
Tray 1,2 Solenoid On/Off
Fan On/Off
Tray 2,3 Clutch On/Off
PTL On/Off
Laser Motor On/Off
Laser Ready On/Off
Diode On/Off
"Sensor Off" or "Sensor
On"
"Cover Open" or "Cover
Close"
"Sensor Off" or "Sensor
On"
Target temperature and
output temperature from
thermistor and ADC.
MHV On/Off
Dev Bias On/Off
THV EN/NEG On/Off
THV On/Off
ADC value displayed.
ADC value displayed.
Workcentre PE 220

Advertisement

Table of Contents
loading

Table of Contents