GOVERNOR : The Governor mixing function is used to adjust the Governor speed settings (rS1, rS2, rS3) from the
transmitter. (If you are using a different governor, follow the manufacturer's instructions.)
The GV-1 controls throttle when it is active, so the throttle will not obey any FailSafe settings preset for throttle in the
and the throttle obeys the FailSafe throttle commands.
Expert Tip: Mounting the Governor to the counter gear instead of the fan
Setting example:
Governor Speed
RS1: OFF
RS2: 1400
RS3: 1700
*The relationship of the governor speed setting rS1~rS3 and the switch positions conforms to the table above.
*In throttle hold, always check that the governor is off.
*If the speed value rises when the cut switch is activated, reverse the " DIR " setting from UP to DOWN or vice versa.
Adjustability:
ch8 and changing CUT-CH setting.
not to assign governor off to a condition switch if you want the governor to
function in that condition.
CH8 can be used for other functions.
be created using an additional channel and a programmable mix. See www.
radiolink.com.cn/doce for details.
Switch Position
(Switch C or Cond.)
UP or NORM
CNTR or IDL1
DOWN or IDL2
Rate (%)
Use up to 0%.
0
(Governor speed display reads "off".)
Speed adjusted by raising and lowering rate.
50
Speed adjusted by lowering rate.
100
87