9. TROUBLESHOOTING

When the engine will not start:
Is there fuel in the tank?
Is the engine switch on?
YES
Is the fuel valve on?
YES
Is there enough oil in the engine?
Is there a spark from
the spark plug?
.
Be sure there is no spilled
fuel around the spark plug. Spilled
fuel may ignite.
Is the fuel reaching the carburetor?
If the engine still does not start, take
the generator to an authorized Kipor
service center.
YES
YES
NO
Replace the
spark plug
NO
Refill the fuel tank.
NO
Turn the engine switch on.
NO
Turn the fuel valve on.
NO
Add the recommended oil.
Still no spark
To check:
1) Remove the spark plug cap and clean any
dirt from around the spark plug.
2) Remove the spark plug and install the s
plug in the plug cap.
3) Set the plug sid
head to ground.
4) Crank
the engine; sparks should jump across
the gap.
To check:
1) Turn off the fuel valve and loosen the d
screw.
2) Fuel should flow from the drain when the fuel
valve is turned on.
- 37 -
Take the generator to
an authorized KIPOR
service center.
e electrode on the cylinder
park
rain