Page 1
Third Stage Development Section of Wangzhuang Industry Area, Wuxi High & New Technology Industry Development Zone Wuxi, Jiangsu Province, PRC TEL: 0086-510-85200888 FAX: 0086-510-85200999 E-MAIL: kipor@kipor.com Version 1, Printing date June 1, 2011 MADE IN CHINA SINEMASTER DIGITAL GENERATOR IG1000, IG1000P...
PREFACE Thank you for purchasing a Kipor generator. This manual covers operation and maintenance of the IG1000, IG2000, and IG2600 generators including parallel versions. All information in this publication is based on the latest product information available at the time of approval for printing.
Page 3
Gives helpful information. If a problem should arise, or if you have any questions about the generator, consult an authorized dealer. Our generators are designed to give safe and dependable service if operated according to instructions. Read and understand the Owner's Manual before operating the generator. Failure to do so could result in personal injury or equipment damage.
1. SAFETY INSTRUCTIONS ■ This generator is designed to give safe and dependable service if operated according to instructions. Read and understand the Owner's Manual before operating the generator. Failure to do so could result in personal injury or equipment damage. ■...
Page 6
■ Always make a pre-operation inspection before you start the engine. You may prevent an accident or equipment damage. ■ Place the generator at least three feet or one meter away from buildings or other equipment during operation. ■ Operate the generator on a level surface to prevent fuel spillage or oil starvation. ■...
2. SAFETY LABEL LOCATIONS These labels warn you potential hazards that can cause serious injury. Read the labels and safety notes and precautions described in manual carefully. If a label comes off or becomes hard to read, contact your dealer for a replacement. CHOKE LEVER LOW OIL ALARM ENGINE SWITCH...
Page 8
FUEL CAP VENT LEVER (Non CARB) CHOKE LEVER FUEL FILLER CAP TYPICALCONTROL MAINTENANCE PANEL COVER STARTER GRIP ENGINE SWITCH SPARK PLUG MAINTENANCE COVER MUFFLER AIR EXHAUST AIR INTAKE...
Page 9
Control panel Smart throttle switch output indicator light overload indicator light Low oil alarm DC receptacle indicator light Ground terminal Overload reset switch overload protector AC receptacle Parallel Control Panel Smart throttle switch output indicator Parallel Receptacles light overload indicator light Low oil alarm DC receptacle...
Page 10
Serial number identification and location The generator serial number identifies your particular unit and is important when ordering parts and accessories. The number is found on a sticker on the carton and on the quality certificate in the carton along with the accessories and owner’s manual. It is also stamped on the engine block visible when the service door is removed.
4. PRE-OPERATION CHECK ■ Be sure to check the generator on a level surface with the engine stopped. 1. Check the engine oil level. ■ Using non detergent oil or 2 cycle engine oil could shorten the engine's service life. Use a high-detergent, premium quality 4-stroke engine oil, certified to meet or exceed U.S.
Page 12
NOTE: The Low Oil Alarm System will automatically stop the engine before the oil level falls below the safe limit. However, to avoid the inconvenience of an unexpected shutdown, it is still advisable to visually inspect the oil level regularly. You must screw down the dipstick completely to measure the oil level.
Page 13
Gasoline containing alternate fuels If you decide to use a gasoline containing ethanol, be sure its octane rating is no lower than the specification. Do not use a blend that contains more than 10% ethanol. Do not use gasoline containing methanol. ■...
Page 14
3. Check the air cleaner Check the air cleaner element to be sure it is clean and in good condition. Loosen the cover screw and remove the left side maintenance cover. Press the latch tab on the top of the air cleaner body, remove the air cleaner cover, check the element.
5. STARTING THE ENGINE Before starting the engine, disconnect any load from the AC receptacle. 1. Turn the engine switch to the ON position. ENGINE SWITCH 2. Move the choke lever to the START position. NOTE: Do not use the choke when the engine is warm or the ambient air temperature is high. START CHOKE LEVER START...
Page 16
■ Do not allow the starter grip to snap back. Return it slowly by hand. STARTER GRIP 4. Move the choke lever to the RUN position after the engine warms up. CHOKE LEVER ■ If the engine stops and will not restart, check the engine oil level before further troubleshooting.
6. GENERATOR USE Be sure to ground the generator when loads are connected. ■ To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a length of heavy cable between the generator's ground terminal and an external ground source.
Page 18
■ The total wattage of all appliances connected must be considered. ■ Do not exceed the current limit specified for any one receptacle. ■ Do not connect the generator to a household circuit. This could cause the damage to the generator or to electrical appliances in the house.
Page 19
AC application 1. Start the engine and make sure only the output indicator light (green) comes on. 2. Confirm that the appliance to be used is switched off, and plug in the appliance. output indicator light overload indicator light 插头 plug ■...
Page 20
Output and Overload Indicators The output indicator light (green) will remain on during normal operating conditions. If the generator is overloaded or if there is a short in the connected appliance, the output indicator light (green) will go out, the overload indicator light (red) will illuminate and current to the connected appliance will be shut off.
Page 21
Overload Reset Switch Should the generator overload, AC power will be cut off but the engine will stay running. Correct the overload condition and then press the overload reset switch on the front panel. AC power will be restored immediately. output indicator light(Green) overload indicator...
Page 22
DC Operation The DC receptacle may be used for charging 12 volt automotive style batteries only, the no load voltage is 15V-30V. ■ In DC operation, turn the Smart-throttle switch to the OFF position. 1. Connect the charging cables to the DC receptacle of the generator and then to the battery terminals.
Page 23
■ The battery gives off explosive gases; keep spark, flames and cigarettes away. Provide adequate ventilation when charging. ■ The battery contains sulfuric acid (electrolyte). Contact with skin or eyes may cause severe burns. Wear protective clothing and a face shield. -If electrolyte gets on your skin, flush with water.
Low oil alarm system The low oil alarm system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase falls below a safe limit, the low oil alarm system will automatically shut down the engine (the engine switch will remain in the ON position).
Page 25
Smart Throttle System When the smart throttle switch is placed in the on position, engine speed is kept at idle automatically when the electrical load is disconnected and returns to the proper speed to match the power of the electrical load when the load is reconnected. This position is recommended to minimize fuel consumption while in operation.
High altitude operation At higher altitudes, the standard carburetor air-fuel mixture will be excessively rich. Performance will decrease, and fuel consumption will increase. Power output will decrease 3.5% for each 1000 feet (305 meters) above sea level. High altitude performance can be improved by installing a smaller diameter main fuel jet in the carburetor.
7. STOPPING THE ENGINE To stop the engine in an emergency, turn the engine switch to the OFF position. IN NORMAL USE: 1. Switch off the connected equipment and pull the inserted plug out. 插头 Plug from appliance 2. Turn the engine switch to the OFF position ENGINE SWITCH...
Any combination of two Kipor parallel ready generators can be connected such as an IG2600 and an IG1000, two IG2000 models, etc. There are two different parallel connection kits. One kit has a 30A receptacle ideal for connecting two IG2000P models or an IG2000P and an IG1000P.
Page 29
Parallel output receptacles Ground connection 3. Ground the generators. 4. Start both generators and confirm that both green "RUN" lights are illuminated. The Smart throttle system may be used as long as the Smart throttle setting of both generators is the same. 5.
Page 30
2. Turn off the two generators. 3. Disconnect the parallel kits from the generators. The parallel cable connectors can only be used with Kipor parallel ready generators. • While connecting the generator and electrical appliance with the parallel output cable, do •...
Carbon monoxide is a poisonous gas. The emission of fuel vapors is a source of pollution as well. The Kipor generator engine utilizes a precise air-fuel ratio and emission control system to reduce the emissions of carbon monoxide, NO , hydrocarbons, and evaporative fuel emissions.
Page 32
You can trust the replacement parts supplied by Kipor have been manufactured to the same production standard as the original parts. The use of replacement parts or accessories which are not designed by Kipor may affect the engine emission performance.
Page 33
The air quality index label is designed to be permanently affixed to the generator and removal should not be attempted. Maintenance Schedule REGULAR SERVICE PERIOD(1) FIRST EVERY 3 EVERY 6 EVERY ITEM EACH MONTH MONTHS MONTHS YEAR Perform at every indicated month or operating hour interval, which- 20HRS 50HRS...
Page 34
1. CHANGING OIL Drain the oil while the engine is still warm to assure rapid and complete draining. ■ Make sure to turn the engine switch and the fuel cap vent lever OFF before draining. 1. Loosen the cover screw and remove the left side maintenance cover. 2.
Page 35
2a. AIR CLEANER SERVICE IG2000 and IG2600 A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dirty areas. ■Do not use gasoline or low flash point solvents for cleaning. They are flammable and explosive under certain conditions.
Page 36
MAINTENANCE COVER AIR CLEANER MAINTENANCE BODY COVER SCREW AIR CLEANER COVER AIR CLEANER COVER SCREW AIR CLEANER ELEMENTS ELEMENT IG2000, IG2600 Service door Air cleaner Latch tab element Screw Air cleaner cover Lower tab IG1000...
Page 37
3. SPARK PLUG MAINTENANCE To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. 1. Remove the spark plug maintenance cover. Spark plug maintenance cover 2. Remove the spark plug cap. 3. Clean any dirt from around the spark plug base. 4.
Page 38
5. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark plug with a wire brush if it is to be reused. 6. Measure the plug gap with a feeler gauge. The gap should be 0.024-0.028in (0.6-0.7mm). Correct as necessary by carefully bending the side electrode.
10. TRANSPORTING and STORAGE To prevent fuel spillage when transporting or during temporary storage, the generator should be secured upright in its normal operating position with the engine switch OFF. When transporting the generator: ■ If you must transport the generator in a vehicle, drain all fuel from the generator. ■...
Page 40
Exercising the Generator It is essential that the generator be exercised on a regular basis. This will prevent the accumulation of varnish or sludge in the fuel system and also remove moisture from the generator windings. Additionally the engine seals and moving components are lubricated. Exercise the generator by running it with at least a 1/2 load for 60 minutes each month.
11. TROUBLESHOOTING Engine will not start: Is there fuel in the tank? Refuel the fuel tank Is the engine switch on? Turn the engine switch on. Is the enough oil in the engine? Add the recommended oil. Still Is there a spark from Replace the the spark plug? spark plug.
Page 42
Appliance does not operate: Is the output indicator light ON? Take the generator to an Is the overload in- authorized dicator light ON? dealer. Check the electrical appli- NO DEFECTS Take the generator to an ance or equipment for any authorized defects dealer.
12. SPECIFICATIONS Generator IG1000 IG2000 IG2600 Model Rated frequency (Hz) Rated voltage (V) Rated current (A) 13.3 19.2 Max current (A) 16.6 21.7 Rated output (W) 1600 2300 Max output (W) 1000 2000 2600 DC Output 12 V, 5.0 A Phase Single Engine...
Kipor distributor will pay for shipping of the unit from the repair center to the designated distributor facility and the shipping of a replacement unit. Kipor or its distributor reserves the right to repair or replace these parts at its option.
You may be denied warranty coverage if a part has failed due to abuse, neglect, improper maintenance, or unapproved applications. You are required to bring your generator to an authorized Kipor generator dealer for repairs as soon as a problem exists.
Page 48
Warranty Provisions 1. Claims Warranty claims shall be filed in accordance with the provisions of the Kipor warranty and policies established with the authorized repair center network. 2. Exclusions Warranty coverage shall be denied for failure of an emissions control system part caused by abuse, neglect, improper maintenance or application as described in the Kipor Generator Owner’s Manual.
2. As the SORE owner, you should however be aware that Kipor may deny your warranty coverage if your SORE or a part has failed due to abuse, neglect, improper maintenance or unapproved modifications.
Page 50
IG2000 1. Fuel System: The fuel tank, cap, indicator and hoses are specially designed and constructed to not allow fuel vapors to permeate and be released to the atmosphere. 2. A carbon activated canister collects gasoline vapors from the fuel tank and returns them to the combustion chamber for burning.
Page 51
Fuel System Fuel Indicator Gas Cap Strainer Washer Gas Cap Sleeve Sleeve Gasket Fuel Tank Cover Bushing Vent Hose Fuel Tank Washer Cotter Pin Certification No. Retention Hook Fuel Hose Vent Hose Fuel Tank Negative Pressure Hose Fuel Hose Fuel Hose Carbon Canister Curved Hose APPENDIX A- IG2600H Handle...
A retractable handle assembly has been designed to facilitate transport of the generator. From the stowed position, simply depress the two yellow buttons on the end of the handle and extend the handle. To retract the handle, simply depress the same buttons and push the handle to the completely stowed position.
Page 53
MOUNTING INSTRUCTIONS FOR THE ACCESSORY LIGHT KIT An accessory light kit is designed specifically for use on the IG1000 or IG2000 generator. Make sure you have the correct kit. Tools required: Phillips head screwdriver Parts supplied: (1) Light Kit Assembly (2) Antiskid Round Nut (3) Antiskid Round Stud (4) Left Mount Plate of Light Kit...